Please enable JavaScript.
Coggle requires JavaScript to display documents.
13GE003 ENGINE - Coggle Diagram
13GE003 ENGINE
2012
2013
2014
2015
-
January
-
-
Date: 22
Event: Carry out the following tasks: 13GE003-300H-MEC-S
HIstory: Replace crankcase lube oil of sump, top-up radiator water coolant
February
-
-
-
-
-
-
-
-
-
Date: 5
Event: Pull out batteries at 13-GE-003 as requested by power station personnel prior to their maintenance works
-
-
Date: 18
Event: First 50hrs maintenance service - after overhaul
History: Changed engine oil, replaced lube oil filters, replaced bypass filter
-
March
Date: 13
Event: Carry out the following tasks: 13GE003-300H-MEC-S
History: Completed-replaced engine oil, engine oil filter,bypass oil filter
-
-
April
-
-
-
-
-
Date: 24
Event: Carry out the following tasks: 13GE003-1200H-ELE-S
History: Inspected-shutters blade not close
-
May
-
-
Date: 23
Event: Carry out the following tasks: 13GE003-300H-MEC-S
History: Replace y strainer and gauge gilter
June
-
Date: 9
Event: Carry out the following tasks: 13GE003-1200H-MEC-S
History: Inspected - Shutter motor for replacement
Date: 28
Event: Carry out the following tasks: 13GE003-300H-MEC-S
History: Replaced lube oil, filter and by pass filter, refill fresh ne lube oil at crankcase sump tank at maximum level and cleaned/checked y strainer
July
-
Date: 11
Event: Carry out the following tasks: 13GE003-2100H-MEC-S
History: Remove air cleaner base and air cleaner elements. Remove all cylinder cover. Pull-out fuel connector, fuel pipe and fuel injector valve 16 pcs. Cleaning of fuel injector sleeve all regular 16pcs. Installed connector pipe, install all cylinder cover, air cleaner base and install air cleaner elements
-
Date: 21
Event: Carry out the following tasks: 13GE003-300H-MEC-S
History: Pull out crankcase cover right-side. Cleaned crankcase and replace ne lube oil. Replace bypass and lube oil filter. Cleaned y strainer and gauge filter. Top up water coolant at radiator
August
-
Date: 17
Event: Carry out the following tasks: 13GE003-300H-MEC-S
History: Pump out crankcase lube oil sump using electric pump. Replace new remula 15W40 to maximum level
Date: 6
Event: Electrical/Instrumentation PM inspection. Include air temperature sensor checks and oil pressure sensor modification.
-
-
-
November
Date: 3*
Event: Carry out the following tasks: 13GE003-1200H-ELE-S
History: No shutter motor at shutter radiator side
-
Date: 14*
Event: Carry out the following tasks: 13GE003-2100H-MEC-S
History: Cleaned injector and replaced fuel injector and adjust tappet clearance. Checked all rackerarm movement
-
-
-
-
January
Date: 11
Event: 300H Powerstation Maintenance Service
History: Changed engine oil, replaced lube oil filters and replaced bypass filter
-
-
-
March
-
-
-
Date: 18
Event: 300H Powerstation Maintenance Service
History: Changed engine lube oil, replaced lube oil filters and replaced bypass filter.
April
-
Date: 13
Event: 300H Powerstation Maintenance Service
History: Changed engine lube oil, replaced lube oil filter, replaced bypass filter
-
May
-
Date: 3
Event: 300H Powerstation Maintenance Service
History: Changed engine lube oil, replaced lube oil filters and replaced bypass filters
Date: 23
Event: Rectify water leaks at cylinders 3, 6, & 14
-
-
Date: 25
Event: Rectify internal leak at cylinder 1, 10, 15 & 16
-
June
Date: 14
Event: 300H Powerstation Maintenance Service
History: Changed engine oil, replaced lube oil filters and replaced bypass filter
Date: 16
Event: 1M Powerstation Genset Maintenance Service
History: Check cleaning fuel system bleed air, check cleaning pre-cleaner, check cleaning air cleaner element, check cleaning engine breathelizer, check cleaning coupling, check cleaning vibration isolating rubber and clean working area
July
-
-
Date: 12
Event: Repair water internal leak on cylinders 4, 5, 8, 12 & 13
History: Replacement of cylinder liner o-ring, rock case gasket cylinder head gasket o-ring packing inlet cylinder liner o-ring, water inlet o-ring
Date: 31
Event: 300H Powerstation Maintenance Service
History: Internal water leaks on cylinder no. 2, 7 & 9
-
-
-
-
-
January
-
-
Date: 26
Event: 1000H Powerstation Maintenance Service
History: Pull-out and replace fuel filters. Pull-out alternator guard belt. Check/adjusted alternator fan belt
Date: 31
Event: 250H Powerstation Maintenance Service
History: Drained used oil, cleaned crankcase oil sump, replaced 4pcs oil filters and refilled new oil
February
Date: 16
Event: 1M Powerstation Maintenance Service
History: Lube oil leak at the back of fuel injection pump left side during operation.
Date: 16
Event: 250H Powerstation Maintenance Service
History: Pulled-out crankcase lube oil manual by using hand pump.Cleaning lube oil crankcase sump.Refilled crankcase oil with remula 15W40 to maximum level. Replaced engine oil,lube oil and bypass filter.Installed cranckcase cover left side and cleaned engine flooring and oil pan.Adjusted valve tappet clearance and check valve mechanism.
March
Date: 8
Event: 250H Powerstation Maintenance Service
History: Changed oil, replaced oil filters and replaced bypass filter.
-
Date: 22
Event: 250H Powerstation Maintenance Service
History: Changed oil, checked radiator coolant, replaced lube oil filters and replaced bypass filter. Adjusted valve tappet clearance, checked valve mechanism and replaced fuel filters.
-
April
Date: 10
Event: 250H Powerstation Maintenance Service
History: Changed oil, replaced by-pass filter, cleaned engine flooring and checked radiator cooling water level
-
-
Date: 23
Event: Check the power, speed signal & wiring of engine hourmeter; try hour meter from standby genset to check if it is really broken/defective.
History: Found analog is defective.
Date: 23
Event: Generator is not synchronizing due to unstable voltage and frequency. Needs fine tuning.
History: Conducted fine tuning of genset but still keep on hunting which can't synchronize and main breaker won't close. Still checking the AVR governor.
-
May
-
Date: 10
Event: 250H Powerstation Maintenance Service
History: Changed oil, replaced oil filters and replaced bypass filter
Date: 23
Event: 1000H Powerstation Maintenance Service
History: Replaced fuel filters, cleaned radiator fins and checked cooling water.
Date: 20
Event: Electrical Inspection of the following:
- Battery Charger
- Radiation Charger
- Engine Hunting issues
-
June
Date: 1
Event: 200H Powerstation Miantenance Service
History: Replaced nozzle tips, changed oil, changed oil filters, changed bypass filter and cleaned radiator fins
-
-
-
-
Date: 22
Event: 250H Powerstation Maintenance Service
History: Changed oil, changed oil filter, changed bypass filter and cleaned engine sump
July
Date: 13
Event: 300H Powerstation Maintenance Service
History: Changed oil, replaced lube oil filters and replaced bypass filter
-
August
Date: 6
Event: 300H Powerstation Maintenance Service
History: Changed oil, changed oil filter and changed bypass filter
-
-
-
-
-
October
-
Date: 13
Event: 300H Powerstation Maintenance Service
History: Changed engine oil, replaced lube oil filters and replaced bypass filter
-
-
November
-
-
Date: 9
Event: Check reverse power alarm
History: Circuit breaker of fuel valve tripped, found out cable was tilted by metal cover plate and fixed cable fuel valve.
-
-
Date: 21
Event: Turbocharge base bolt inspection. Retight and repair of front/ tear covers
History: Repaired damage cover
-
-
-
-
-