Please enable JavaScript.
Coggle requires JavaScript to display documents.
Power Sources - Coggle Diagram
Power Sources
Battery Pack
Fuel Gauge
State of Charge (SoC)
Algorithm
Voltage Only for Coulomb Counting (CC)
Compensated End of Discharge (CEDV)
Impedance Track (IT)
Battery Voltage (OCV)
State of Health (SoH)
Battery Current
Battery Temperature
Ramain Capacity (RM)
Fully Charge Capacity (FCC)
Charge Count
Types
1P2S
2S1P
Charger
Protection
Over Voltage Protection
Under Voltage Protection
Over Current Protection
Short Circuit Protection
Over Temperature Protection
Under Temperature Protection
Thermal Regulator
Safety
JEITA
Pre-Charging
Trickle Current Charging
Constant Current Charging
Constant Voltage Charging
Folating Current Charging
Topologies
Linear
Switching
Buck
Boost
Buck-Boost
Switching Frequency
Others
Standby Current
Idle Current
Charging Current
Battery Cell Types
Li-ion
18650
21700
Polymer Li-ion
Characteristics
Self-Discharging Rate at Different Storage Conditions
DC Impedance at Different Storage Conditions
ACR During Cycles
Cycles - Charging / Discharging
DCR During Cycles
DCR at Different Temperatures
ACR at Different Temperatures
Discharging Rate at Different Temperatures
Rate of Temperature Rise During Dischage
Wire
DC Source
PoE
Pulse XFMR
Impedance
Inductance
Insulation Range
Magnetic Flux
Fequency
PoE IC
Operation Temperature Range
Input Operation Voltage Range
Input Absolute Voltage Range
Solar Power
Output Power Rating @ STC
Output Voltage Range
Operation Temperature Range
Ingress Protection Level
Cable Types and Length
Impedaance
Wire Size - AWG
Press Resistant
Insulation Impedance
Voltage / Current Rating
Operating Temperature Range
Connector Types
Reliability
Thermal Cycling
85/85
Warranty
Anti UV Resistance
AC Source
AC Low Voltage for Buildings
AC to AC XFMR Voltage Range
AC to AC XFMR VAC Power Rating
AC-DC Adapter
Input Characteristics
AC/DC Input Voltage Range
Input Inrush Current
AC/DC Absolution Voltage Range
Brun In / Out
Power Factor Correction (P.F.C)
Leakage Current
Input Power Loss in No Load
Output Characteristics
Output Voltage Setpoint Tolerance
Output Voltage Line Regulation
Output Voltage Load Regulation
Output Voltage Ripple and Noise
Output Voltage Dynamic & Response
Hold Up Time
Turn On Delay / Rise Time
Closed Loop Feedback Controller - Phase . Gain Margin
Output Load Range / Power Rating
Protection Characteristics
Input Over Voltage Protection
Output Over Voltage Protection
Output Over Current Protection
Output Short Circuit Protection
Over Temperature Protection
Ingress Protection Level
Anti-UV Resistance
Safety
CEC/DoE Level VI
UL62368-1
FCC
IEC61000
Others
Operation Temperature Range
Housing / Cable Color
Cable Types and Length
Impedance
Wire Size - AWG
Press Resistant
Insulation Impedance
Voltage / Current Rating
Operating Temperature Range
Connector Types
AC Power Cord Types
Reliability
Stress
Thermal
E-Cap Life
MTBF
Warranty
On Board Power Solation
AC Input
Indoor
Outdoor
DC Input
Indoor
Outdoor
Input Power Source
EMS
EMI
Conduction Emission (CE)
Radiation Emission (RE)
EMC
ElectroStatic Discharge (ESD)
Level 3 (Contact ±6kV ; Air ±8kV)
Leve 2 (Contact ±4kV ; Air ±4kV)
Level 4 (Contact ±8kV ; Air ±15kV)
Level 1 (Contact ±2kV ; Air ±2kV)
Electircal Fast Transient (EFT)
Level 1 (L1L2-PE ±0.5kV ; I/O signal ±0.25kV)
Level 2 (L1L2-PE ±1kV ; I/O signal ±0.5kV)
Level 3 (L1L2-PE ±2kV ; I/O signal ±1kV)
Level 4 (L1L2-PE ±4kV ; I/O signal ±2kV)
Surge
Level 2 (L1-L2 ±0.5kV ; L1L2-PE ±1kV)
Level 3 (L1-L2 ±1kV ; L1L2-PE ±2kV)
Level 1 (L1-L2 ; L1L2-PE ±0.5kV)
Level 4 (L1-L2 ±2kV ; L1L2-PE ±4kV)