Please enable JavaScript.
Coggle requires JavaScript to display documents.
LDV-B- 60kw-400V - Coggle Diagram
LDV-B- 60kw-400V
Engine
-
Coupling, non-sparking guard
Starting
-
Hydraulic Starter skid: Class I, Zone 2, IIA, T3 (to be installed part of skid)
-
DEG skid: Class I, Zone 2, IIA, T3
-
Dual filter: fuel, lube oil
Pre-lube pump: driven by DC pump- powered by starting batt or air compressor ( when starting by air)
Alternator
-
-
-
-
-
DEG skid: Class I, Zone 2, IIA, T3
RTD: 6 x winding, 2 x bearing
Class F insulation, Class B temp rise
Misc.
-
-
-
Skid mounted day tank 18 hrs, carbon steel, flame arrestor vent ( loose)
spare part: pre-com, com, insurance part
3D PDMS model (piping, structures) + PDMS catalogue+ spec
-
IP note
-
UCP, electrical junction boxes, battery charger, Isolator: IP56
-
-
-
-
-
LCP
out door, Zone 2, IIA, T3
all instrument devices
Cabling, junction boxes: zone 1, IIA, T3
instrument cables: flame retardant- IEC 60332, low smoke, fume emission
junction box: SS316, Exe, IP56
instrument tubing: SS316L, 2.5% molydenum
-