FPU DH-01- 02 units x 2304/2400KVA, 600V, 60hz ( đang chọn C175-16 petro…
FPU DH-01- 02 units x 2304/2400KVA, 600V, 60hz ( đang chọn C175-16 petro genset)
Engine
-
-
survey & convert: cooling water system, cooling oil system ( phần nội dung này khách chưa gửi lại thông tin? ko biết có khách có ý đinh dùng lại hệ cũ ko?)
SS316L exhaust system, spark arrestor, flame trap
-
emission: NOx, SOx, CO2, VOC - meet local authority requirement
-
-
-
Local Control stations (LCS) with hand-off-auto selector switches complete with emergency push button for all auxiliary motors.
Common fabricated structural skid- complete with drip pan under the diesel engine; anti-vibration mountings
-
Alternator
-
2304/2400KVA; insulation class F, class B temp rise
-
-
-
-
-
IP56 terminal box, IP54 for alternator
-
-
-
UCP (stand alone)
-
-
-
Synchronizing, load share
interface: switchboard, ICSS
all cables, cables gland from genset to UCP
One diagnostic laptop for the UCP with all configuration software and licenses- trouble shooting purpose
The electronic unit governor shall be installed in the UCP whereas the engine-mounted unit shall be within the DEG skid ( Phuong note: in UCP is for synch. function)
-
-
-
lifting, tool set
lifting beam, slings, shackles, 3rd certificate
Training
for 10 pax, class room/site
-
-
-
A loose- supplied pneumatic starting skid (loose supplied) for 4 DEGs, including 2x100% air compressor, 2x100% air bottles, necessary piping, valves, fittings and instruments.
-
minimum four (4) lifting lugs, for single point lift during transportation and installation