Design methodology
Slab
Type
-
Non-composite
-
Timber
Often supported on steel beams, but can use engineered timber joists (e.g. timber I-sections)
Loading
-
Live
-
-
-
-
Construction, typ. 1.5 kN/m2
-
Beams
Primary
Preliminary dimensions
Span, typ. 6-9m, max. 15m
Depth, span/20 for floor, span/25 for roof
Secondary
Preliminary dimensions
Spacing, typically between 2.4 and 3.0m, but can go up to 4.5m
Span, typ. up to 16m (12m from IStructE)
Depth, span/25 for both floor and roof
Capacity checks
-
-
Deflection
-
Carrying brittle finishes, span/360
-
-
-
-
-
Foundations
Capacity checks
Preliminary design
-
Types
Shallow foundations
-
Sizing
Pad / strip footings
Mass concrete
Depth >= 300 mm, <= 3000mm
Ratios of projection (of footing from column face) to depth (of footing), dependent on concrete grade and allowable bearing pressure (IStructE Design Manual to EC2, 5.10.5.1)
Reinforced concrete
Similar depth/projection ratios (IStructE DM to EC2, 5.10.5.2)
Depth = effective depth + bar diameter/2 + cover <= 3000mm
Effective depth (depth from upper face to rebar centreline) >= 300mm.
Cover = typ. 75 mm
-
Raft
If raft is sufficiently rigid, pressure can be distributed over entire area; however, a large raft is unlikely to be sufficiently rigid
For less rigid rafts, applied bearing pressure = column load / raft area of column, q = W_col / (L_col × B_col)
Where:
L_col = column spacing in one orthogonal direction; and,
B_col = column spacing in other orthogonal direction.
Pressure distribution in a flexible raft is complicated; dependent on column spacing, soil stiffness and rigidity of the raft
- 2 more items...
Deep foundations
Piles
-
Sizing
-
Spacing
Pile spacing >= 3 × pile diameter, centreline to centreline
Pile caps
+/- 75mm tolerance on plan, therefore pile caps should 150mm beyond edge of piles to allow tolerance + 75mm cover
-
-
-
Loading
Imposed loading (BS EN 1991-1-1, Tables NA.2 and NA.3)
Residential
Balcony
-
in hostels, guest houses and residential clubs
-
-
-
-
-
Generic
-
Areas with tables
-
Public, institutional and communal dining rooms and lounges, cafes and restaurants
-
-
-
-
-
-
-
-
-
-
-
-
Permanent loads
-
Dead loads
“For steel buildings an allowance is often made on plan area for the weight of steelwork – typically 0.5 kN/m2 at floor levels” (IStructE, Conceptual design of buildings, 2021, p.152)
Columns
Is it common to just use the same column section for the entire vertical 'stack', or to vary sections as the loads reduce further up the stack?
-
What is the typical length of each section in the column stack? Presumably greater than the floor-to-floor height (i.e. the same column section would span multiple floors)?
-