Micromirror Failures
Start
Infant Mortality Phase
Rough topography
Exceed acceptable temperature for fabrication
Lack of certain parts (E.g. Spring Tips)
Poor particle Control (Microcontamination)
Mishandling of MEMs device during transportation
Physical charged contact on human/machine
Usable Period
Out of Temperature Range
Drops
Favourable Condition for Pest
Vibrations
Excessive Voltage
Moisture (Humidity)
Wear-Out Period
Hinge Fracture caused by Torsional micromirror
Electrostatic discharge
Stictions
Wear Debris
Gear Surface
Manufacturing Defects
External & Internal Parameters
Microscopic Defects