SU TU NAU-GAS GENSET ( 120KW GAS -G3306TA + 120 KW DIESEL) OR 300KW -GAS…
SU TU NAU-GAS GENSET ( 120KW GAS -G3306TA + 120 KW DIESEL) OR 300KW -GAS G3412 TA - 1800 RPM
Engine
Radiator
Starting
Primary: Electric
Motor starter: Exnr
Secondary: hydraulic
Lube Oil:
Filter: duplex type
Breather flame trap
Change over valve for filter
Air intake
Shut off valve
Exhaust system
Dry insulated with Ceramic Coating: below 200C degree surface
Spark arrestor muffler ( SS316)
Exhaust piping: SS316
Governor: IP56 or Nema 4
operate 8,000 hrs/year
Enclosure: 85 dBA@ 1m
Weather proof
Junction box: refer inquiry of spec (zone + type)
Alternator
ATEX/FM/UL
Offshore
480V, 1800 RPM
Insulation:F, temp rise: B
IP56, CACA (data sheet); NEMA MG2 and IP 54 (spec)
double bearing
max bearing design: 140 C at 115%
random wound (data sheet), form wound ( spec)
seperate box for RTD (bearing, wiring, cooling), space heater, AC& DC system
heater: 120V, 1ph, 60hz
redundant AVR (DECS 200- Basler)
3 x DCT (free issued by LV vendor) ; ground fault CT, cross current CT
vibration monitoring
4 x RTD for bearing (spec), 9 x RTD for winding (spec)
Alternator Testing