BMS Compliance
ELECTRICAL
Conducted Immunity as per ISO 7637-2
Conducted Immunity on Signal Lines as per ISO 7637-3
Conducted Transient Emissions as per ISO 7637-2
Conducted Emissions as per CISPR 25: Class 3
Radiated Emissions: as per CISPR 25: Class 3
Radiated Immunity (ALSE) as per ISO 11452-2: 100 V/m
Radiated Immunity (BCI) as per ISO 11452-4: 100 mA
Immunity against interference from portable transmitters as per ISO 11452-9
Immunity against magnetic fields: ISO 11452-8
ESD tests as per ISO 10605
Electrical tests as per ISO 16750-2
Electrical tests on 12V supply rail as per LV124
Electrical tests on 48V supply rail as per LV148
MECHANICAL
Corrosion Test with Flow of Mixed Gases (ISO 16750-4)
Damp Heat Steady State (ISO 16750-4)
Humid Heat Cycle (ISO 16750-4)
Ice Water Shock Test (ISO 16750-4)
Temperature Cycling (ISO 16750-4)
Temperature Steps (ISO 16750-4)
Tests at constant temperature
Gravel Bombardment Test (ISO 16750-3)
Free Fall/ Drop Test (ISO 16750-3)
Resistance to Salt Spray (IEC 60068-2-11/ ISO16750-4)
Type of protection (DIN / EN 60529 or ISO 16750-4)
(Without / with mounted mating connector)
Resistance to Moisture (IEC 60068-2-30 Db; Variant 2)
Continuous Shock (IEC 60068-2-29/ ISO 16750-3)
Transport Shock (IEC 60068-2-27/ ISO 16750-3)
Random Vibration (IEC 60068-2-36)
Sinusoidal Vibration (IEC 60068-2-6/ ISO 16750-3)