Loudspeaker system calibration

Tuning with Networkmanager simulation and measurement of acoustical responses

Measure the response of a defined set of sources for a defined set of locations

Equalize each main source to correct stable irregularities

Align the main full-range source and its frequency complements (typically main sub-low source and possibly main infra-low source) to create a coherent main system

Equalize the main system to match a reference frequency contour

Align the main system and its spatial complements (namely all kind of fill systems) in level, frequency response and time.

Verification with Soundvision simulation project and reality on site

Verify that the Soundvision design project used as a reference is valid.

Layout (number and relative position of sources)

Sources (loudspeaker types and number)

Actual venue dimensions

Audience geometry

vertical cutview of the main full-range source

width of the venue

obstructive objects

Verify that the system is implemented as planned in the reference project.

Verify that the system is functional

Implemented locations match with the locations planned in the design

electronic settings

Networkmanager setup check

pink noise (only one group, and simultaneous groups)

listening tests with musical tracks

Apply the symmetry

Listen

8 ideally, ground, Zebra config, with name locations

EQ, observ stable bump and correct it.