DFOG Fan Sensor Repair
open blower access area
swap B and C fan sensors and test
no ticks on B
no ticks on C
fan sensor on C is bad
and
wiring upstream on C is bad
ticks on C
fan sensor on C is bad
and
wiring upstream on C is good
Issue:
Fan sensor on C is still bad
Check if sensor is mounted correctly:
-flat
-label facing up
-no ubstruction
sensor mounted well
Fix:
Replace fan sensor again
sensor not mounted well
Fix:
Refit sensor on C and start over
ticks on B
no ticks on C
wiring upstream on C is bad
and
fan sensor on C is good
Issue:
Wiring upstream on C is bad
Replace fans on B and C to
correct plugs and ensure they
are plugged in well
and
open electronics compartment
above blowers
replace wire connected to fan on C
close up electronics compartment
gently and test again
3 more items...
ticks on C
wiring upstream on C is good
and
fan sensor on C is good
Issue:
Fan sensor plug on C was loose
Fix:
Replace fans on B and C to correct plugs and ensure they are plugged in well